Difference between revisions of "C0Q Quality Reporting 1.0"

From VistApedia
Jump to: navigation, search
(INSTRUCTIONS:)
Line 28: Line 28:
 
::- The install steps assume the VistA software is already installed and the environment variables/aliases are defined in your system.  
 
::- The install steps assume the VistA software is already installed and the environment variables/aliases are defined in your system.  
 
::- These instructions assume you are logged into VistA as a user who has access to configure the C0Q package.
 
::- These instructions assume you are logged into VistA as a user who has access to configure the C0Q package.
 
=== INSTRUCTIONS: ===
 
 
:1. Set-up MU Measure Parameters
 
:: Log into VistA (user must have access to C0Q package).  From GTM prompt:
 
<pre style="padding:1em;border:1px dashed #2f6fab;color:black;background-color:#f9f9f9;line-height:1.1em">
 
GTM>D ^XUP -- enter the programmer environment
 
Select OPTION NAME: COQ Q -- enter C0Q module
 
    1  C0Q QUALITY MEASURE DEFINITION      QUALITY MEASURE DEFINITION
 
    2  C0Q QUALITY MEASUREMENT MENU      QUALITY MEASUREMENT MENU
 
CHOOSE 1-2: 2  C0Q QUALITY MEASUREMENT MENU    QUALITY MEASUREMENT MENU
 
Select QUALITY MEASUREMENT MENU Option: SETUP QUALITY REPORTING -- menu for C0Q set-up
 
 
 
          DISPLAY QUALITY MEASURES
 
          EDIT SUPERUSERS
 
          EP EDIT PARMS
 
          INP EDIT PARMS
 
          MEASURE SET EDIT
 
          MU MEASURE EDIT
 
          QUALITY MEASURE EDIT
 
 
Select SETUP QUALITY REPORTING Option: EP EDIT PARMS
 
</pre>
 
::Prior to building measures and measure sets, we must establish the parameters.  If you’re building outpatient MU measures, “EP EDIT PARMS” should be selected (as seen above).  If you’re building, inpatient MU measure, “INP EDIT PARMS” should be selected.
 
<pre style="padding:1em;border:1px dashed #2f6fab;color:black;background-color:#f9f9f9;line-height:1.1em">
 
Select C0Q PARAMETER NAME: MU2012 Clinic Reporting -- Enter Name of Parameter
 
  Are you adding 'MU2012 Clinic Reporting' as
 
    a new C0Q PARAMETER (the 1ST)? No// y  (Yes)
 
NAME: MU2012 Clinic Reporting  Replace
 
MEASUREMENT PERIOD KEY: MU12 -- Period Key groups measures and lists so easy to locate and search
 
PARAMETER TYPE:  OUTPATIENT -- defines criteria for MU Measure data
 
EP MU MEASUREMENT SET: -- To be left empty for now.  Will come back to add measure set.
 
EP QUALITY MEASUREMENT SET:
 
Select CLINIC: DR OFFICE      DOCTOR,FOUR --defines visit criteria.  To ONLY look for visits in a specific clinic, ward, etc.
 
  Are you adding 'DR OFFICE' as a new CLINIC (the 1ST for this C0Q PARAMETER)?
 
No// y  (Yes)
 
Select CLINIC: -- You may add a second clinic/location if you wish
 
PATIENT LIST LABEL:
 
Select SUBSCRIBER:
 
</pre>
 
::End of MU Measure Parameter Set-up.  [Enter] out of the menu until you reach the QUALITY MEASUREMENT MENU (C0Q Q menu as seen below): 
 
 
 
:2. Update MU Measures
 
<pre style="padding:1em;border:1px dashed #2f6fab;color:black;background-color:#f9f9f9;line-height:1.1em">
 
GTM>D ^XUP -- enter the programmer environment
 
Select OPTION NAME: COQ Q -- enter C0Q module
 
 
COPY OVER PATIENT LISTS
 
          ED-1 COMPUTATION
 
          ED-2 COMPUTATION
 
          EP UPDATE MU MEASURES
 
          INP UPDATE MU MEASURES
 
          PQRI MENU ...
 
          PQRI PRINT XML
 
PRINT C0Q MEASURES
 
          SETUP QUALITY REPORTING ...
 
 
Select QUALITY MEASUREMENT MENU Option: EP UPDATE MU MEASURES
 
Jul 25, 2011@98:87:94
 
Jul 25, 2011@87:88:53
 
Jun 27, 2011@97:94:70
 
Jun 27, 2011@97:89:96
 
BAD HEALTH FACTOR: Non-Smoker (PMH)
 
BAD HEALTH FACTOR: Non-Tobacco User
 
BAD HEALTH FACTOR: Current Smoker - No
 
BAD HEALTH FACTOR: Current Smoker - Yes
 
CREATING MU12-EP-ALL-PATIENTS
 
CREATING MU12-EP-DR OFFICE-Patient
 
CREATING MU12-EP-FailedDemographics
 
CREATING MU12-EP-HasAllergy
 
</pre>
 
::If you are building Inpatient MU Measures, select INP UPDATE MU MEASURES instead of EP UPDATE MU MEASURES (as selected above).  Once you select “UPDATE MU MEASURE” you should see several lines of text (a small subset of this text can be seen above).  When selecting the UPDATE MU MEASURES option, the parameters for Clinics or Inpatient facilities for the Meaningful Use measures are being computed. The parameters then update the patient lists associated with the MU measures, creating new lists (lists are auto-generated for MU measures) only if none exist. They then look for MU Measurement Sets that are in the parameters, and update them, copying over numerator and denominator patient lists, counting them, and computing the percentage.  A final update should be performed to ensure the most up-to date data is reported for your MU measure/measure set (see step 6).
 
 
 
:3. Create MU Measures
 
<pre style="padding:1em;border:1px dashed #2f6fab;color:black;background-color:#f9f9f9;line-height:1.1em">
 
GTM>D ^XUP -- enter the programmer environment
 
Select OPTION NAME: COQ Q -- enter C0Q module
 
    1  C0Q QUALITY MEASURE DEFINITION      QUALITY MEASURE DEFINITION
 
    2  C0Q QUALITY MEASUREMENT MENU      QUALITY MEASUREMENT MENU
 
CHOOSE 1-2: 2  C0Q QUALITY MEASUREMENT MENU    QUALITY MEASUREMENT MENU
 
 
          COPY OVER PATIENT LISTS
 
          ED-1 COMPUTATION
 
          ED-2 COMPUTATION
 
          EP UPDATE MU MEASURES
 
          INP UPDATE MU MEASURES
 
          PQRI MENU ...
 
          PQRI PRINT XML
 
          PRINT C0Q MEASURES
 
          SETUP QUALITY REPORTING ...
 
 
Select QUALITY MEASUREMENT MENU Option: SETUP QUALITY REPORTING
 
 
 
          DISPLAY QUALITY MEASURES
 
          EDIT SUPERUSERS
 
          EP EDIT PARMS
 
          INP EDIT PARMS
 
          MEASURE SET EDIT
 
          MU MEASURE EDIT
 
          QUALITY MEASURE EDIT
 
 
Select SETUP QUALITY REPORTING Option: MU MEASURE EDIT
 
 
Select C0Q QUALITY MEASURE NAME: MU12 Allergy -- MU12 Allergy is name of my measure
 
  Are you adding 'MU12 Allergy' as a new C0Q QUALITY MEASURE (the 103RD)? No//
 
y  (Yes)
 
  C0Q QUALITY MEASURE DISPLAY NAME: Allergy List -- Allergy List is my display name
 
NAME: MU12 Allergy// -- Hit Enter to accept the default answer (same as name given)
 
MU YEAR KEY: MU12 -- Hit Enter to accept the default answer
 
TITLE: -- Hit Enter to bypass (optional)
 
VERY LONG DESCRIPTION: -- Hit Enter to bypass (optional)
 
  1>
 
DISPLAY NAME: Allergy List // -- Hit Enter to accept the default answer
 
REPORTING NAME:    
 
ALTERNATIVE NUMERATOR LIST: MU12 -- list used as the numerator to calculate measure percentage
 
    1  MU12-EP-ALL-PATIENTS      MU12-EP-ALL-PATIENTS
 
    2  MU12-EP-DR OFFICE-Patient      MU12-EP-DR OFFICE-Patient
 
    3  MU12-EP-FailedDemographics      MU12-EP-FailedDemographics
 
    4  MU12-EP-HasAllergy      MU12-EP-HasAllergy
 
    5  MU12-EP-HasDemographics      MU12-EP-HasDemographics
 
Press <RETURN> to see more, '^' to exit this list, OR
 
CHOOSE 1-5: 4  MU12-EP-HasAllergy    MU12-EP-HasAllergy
 
ALTERNATIVE DENOMINATOR LIST: MU12 -- list used as the denominator to calculate measure percentage
 
    1  MU12-EP-ALL-PATIENTS      MU12-EP-ALL-PATIENTS
 
    2  MU12-EP-DR OFFICE-Patient      MU12-EP-DR OFFICE-Patient
 
    3  MU12-EP-FailedDemographics      MU12-EP-FailedDemographics
 
    4  MU12-EP-HasAllergy      MU12-EP-HasAllergy
 
    5  MU12-EP-HasDemographics      MU12-EP-HasDemographics
 
Press <RETURN> to see more, '^' to exit this list, OR
 
CHOOSE 1-5: 1  MU12-EP-ALL-PATIENTS    MU12-EP-ALL-PATIENTS
 
 
Select C0Q QUALITY MEASURE NAME:
 
</pre>
 
::From year to year some MU measures may use the same numerator and dominator lists.  If this applies to you, you can simply re-use and rename a measure instead of building a new measure from scratch.  Also, in this example we only created one measure to be included in our MU measure set.  If you would like multiple measures to be included, you would create additional measures and name accordingly.  Please note:  Consistent naming is crucial for keeping measures organized.
 
 
 
:4. Create MU Measure SET and add MU Measure(s)
 
<pre style="padding:1em;border:1px dashed #2f6fab;color:black;background-color:#f9f9f9;line-height:1.1em">
 
GTM>D ^XUP -- enter the programmer environment
 
Select OPTION NAME: COQ Q -- enter C0Q module
 
    1  C0Q QUALITY MEASURE DEFINITION      QUALITY MEASURE DEFINITION
 
    2  C0Q QUALITY MEASUREMENT MENU      QUALITY MEASUREMENT MENU
 
CHOOSE 1-2: 2  C0Q QUALITY MEASUREMENT MENU    QUALITY MEASUREMENT MENU
 
 
          COPY OVER PATIENT LISTS
 
          ED-1 COMPUTATION
 
          ED-2 COMPUTATION
 
          EP UPDATE MU MEASURES
 
          INP UPDATE MU MEASURES
 
          PQRI MENU ...
 
          PQRI PRINT XML
 
          PRINT C0Q MEASURES
 
          SETUP QUALITY REPORTING ...
 
 
Select QUALITY MEASUREMENT MENU Option: SETUP QUALITY REPORTING
 
Select SETUP QUALITY REPORTING Option: MEASURE SET EDIT
 
 
Select C0Q MEASUREMENTS SET NAME: MU12 Measure Set -- MU12 Measure set is name of my measure set
 
  Are you adding 'MU12 EP Measure Set' as
 
    a new C0Q MEASUREMENTS (the 10TH)? No// y  (Yes)
 
SET NAME: MU12 EP Measure Set// -- Hit Enter to accept the default answer
 
BEGIN DATE: 1-1-2012  (JAN 01, 2012) -- Beginning Date of visits to be included in the measure set
 
END DATE: 12-31-2012  (DEC 31, 2012) -- Ending Date of visits to be included in the measure set
 
LOCKED: -- Can Lock the Measure Set once completed
 
MU YEAR KEY: MU12 -- Key is same as period Key used above
 
Select MEASURE: MU12 -- Add the MU measures created in step 3 to create your measure set
 
    1  MU12 Allergy      Allergy List
 
CHOOSE 1-3: 1  MU12 Allergy    Allergy List
 
  Are you adding 'MU12 Allergy' as a new MEASURE (the 1ST for this C0Q MEASUREM
 
ENTS)? No// y  (Yes)
 
  NUMERATOR FILTER LIST:
 
  DENOMINATOR FILTER LIST:
 
Select MEASURE:
 
 
Select C0Q MEASUREMENTS SET NAME:
 
</pre>
 
::All applicable MU Measures created in Step 3 should be added to your Measure Set.
 
 
 
:5. Link Measure Set to Parameter
 
<pre style="padding:1em;border:1px dashed #2f6fab;color:black;background-color:#f9f9f9;line-height:1.1em">
 
GTM>D ^XUP -- enter the programmer environment
 
Select OPTION NAME: COQ Q -- enter C0Q module
 
    1  C0Q QUALITY MEASURE DEFINITION      QUALITY MEASURE DEFINITION
 
    2  C0Q QUALITY MEASUREMENT MENU      QUALITY MEASUREMENT MENU
 
CHOOSE 1-2: 2  C0Q QUALITY MEASUREMENT MENU    QUALITY MEASUREMENT MENU
 
 
        COPY OVER PATIENT LISTS
 
          ED-1 COMPUTATION
 
          ED-2 COMPUTATION
 
          EP UPDATE MU MEASURES
 
          INP UPDATE MU MEASURES
 
          PQRI MENU ...
 
          PQRI PRINT XML
 
          PRINT C0Q MEASURES
 
          SETUP QUALITY REPORTING ...
 
 
Select QUALITY MEASUREMENT MENU Option: SET-UP QUALITY REPORTING
 
 
          DISPLAY QUALITY MEASURES
 
          EDIT SUPERUSERS
 
          EP EDIT PARMS
 
          INP EDIT PARMS
 
          MEASURE SET EDIT
 
          MU MEASURE EDIT
 
          QUALITY MEASURE EDIT
 
 
Select SETUP QUALITY REPORTING Option: EP EDIT PARMS -- or INP EDIT PARMS depending on INP or OP
 
Select C0Q PARAMETER NAME: MU12  MU2012 Clinic Reporting -- Parameter created in Step 1
 
NAME: MU2012 Clinic Reporting  Replace -- Hit Enter to accept the default answer
 
MEASUREMENT PERIOD KEY: MU12// -- Hit Enter to accept the default answer
 
PARAMETER TYPE: OUTPATIENT// -- Hit Enter to accept the default answer
 
EP MU MEASUREMENT SET: MU12 EP Measure Set  -- Add MU Measure Set created in Step 5
 
EP QUALITY MEASUREMENT SET: -- Hit Enter to accept the default answer
 
Select CLINIC: DR OFFICE// -- Hit Enter to accept the default answer
 
PATIENT LIST LABEL: -- Hit Enter to accept the default answer
 
Select SUBSCRIBER: -- Hit Enter to accept the default answer
 
 
Select C0Q PARAMETER NAME:
 
</pre>
 
:: Your MU Measure Set (which includes MU Measures and visit time frame) is now linked to your parameter.  **MU MEASURE BUILD IS COMPLETE**
 
 
 
:6. Update MU Measure(s)
 
::Prior to printing or displaying MU Measure perform an UPDATE MU MEASURE.  This will ensure we are printing or displaying the most up to date data in the system.  To complete this task, follow the instructions outlined in Step 2. 
 
 
 
:7. Print C0Q Measures
 
<pre style="padding:1em;border:1px dashed #2f6fab;color:black;background-color:#f9f9f9;line-height:1.1em">
 
GTM>D ^XUP -- enter the programmer environment
 
Select OPTION NAME: COQ Q -- enter C0Q module
 
    1  C0Q QUALITY MEASURE DEFINITION      QUALITY MEASURE DEFINITION
 
    2  C0Q QUALITY MEASUREMENT MENU      QUALITY MEASUREMENT MENU
 
CHOOSE 1-2: 2  C0Q QUALITY MEASUREMENT MENU    QUALITY MEASUREMENT MENU
 
 
COPY OVER PATIENT LISTS
 
          ED-1 COMPUTATION
 
          ED-2 COMPUTATION
 
          EP UPDATE MU MEASURES
 
          INP UPDATE MU MEASURES
 
          PQRI MENU ...
 
          PQRI PRINT XML
 
          PRINT C0Q MEASURES
 
          SETUP QUALITY REPORTING ...
 
 
Select QUALITY MEASUREMENT MENU Option: Print C0Q MEASURES
 
Select C0Q MEASUREMENTS SET NAME: MU12 EP Measure Set 
 
 
DEVICE:  TELNET
 
C0Q MEASUREMENTS LIST                          MAR  7,2012  08:20    PAGE 1
 
MEASURE:DISPLAY NAME      DENOMINATOR    NUMERATOR          PERCENTAGE
 
--------------------------------------------------------------------------------
 
 
 
Allergy List                      55            23            42.00
 
</pre>
 
::Following Build, the above steps will allow you to view (validate the build) and print the MU Measure build created.
 
  
 
== Verifying the Installation ==
 
== Verifying the Installation ==

Revision as of 15:24, 21 March 2012

What is C0Q Quality Reporting?

back: VistA_Meaningful_Use_Enhancements

The C0Q Quality Reporting Package is a mumps-based addition to VistA for reporting Meaningful Use and Quality Measurements. The package supports both inpatient and outpatient reporting, and computes the Meaningful Use measures from patient records. For Quality Measurements, the reporting package relies on the VistA Reminders Patient Lists as the source for its reporting.

PQRI xml sample file


Licensing

Installing C0Q Quality Reporting

System Requirements

Infrastructure Dependencies

VistA Package Dependencies

Downloading the Software

Installation and Configuration

C0Q PACKAGE - CONFIGURATION of MEANINGFUL USE (MU) MEASURES

ASSUMPTIONS:

- The install guide applies to VistA systems running on Linux/GT.M
- The install steps assume the VistA software is already installed and the environment variables/aliases are defined in your system.
- These instructions assume you are logged into VistA as a user who has access to configure the C0Q package.

Verifying the Installation

Contributors

Future Development