This is a bird's eye view of how to set-up lab in VISTA. For all I know, it may be wrong, as I have never done the lab set-up before.

Before you start

  • Keys needed: LRLIASON, LRLAB, LRVERIFY, LRSUPER

File 69.9 - Laboratory Site

One Entry via Fileman; Important Fields:

  • Insitution
  • Hospital location containing OOS
  • Time Order Stamps
  • Which Printers to Use

File 68 - Accession Areas

Entries via Fileman; Important Fields:

  • Subscript to use for each accession area
  • Accession Transform
  • Barcode Algorithm (39 or 128)

Adding Lab Tests

  • Add Data Names for each single test: via Menu Option: LRMENU > Supervisor > Lab Liason > DATA
  • Add Lab Test via Fileman; Important Notes
    • Type: BOTH = Input and Output. ie, can be ordered and resulted. Input only: Can be ordered (e.g. Panel). Output only: Can be resulted only. Neither: Can neither be ordered nor resulted. Use to inactivate tests. If test is old but has results, need to change it to just Output; otherwise, results will disappear from the CPRS screen.
    • A lab test can be single or a panel ("cosmic").
    • Panels, Micro tests, Anatomic Pathology tests don't get data names
    • Single tests needs unique data names
    • All tests need unique print name
    • Unique